What is a good heart rate recovery?

Kento Health

Kento Health

In clinical exercise testing, heart rate recovery is how much your heart rate falls in the first minute after you stop at peak effort. In the best-known studies, a fall of 12 beats per minute or less, measured during a light cool-down, was counted as abnormal [1, 3]. A larger fall went with lower long-term risk [5].

Heart rate recovery has more than 25 years of clinical research behind it, measured with ECG during exercise tests, not with a watch. Here is what that research measured, what it found, and how far a wrist estimate can take you.

What is heart rate recovery?

Heart rate recovery is the drop in your heart rate between the end of hard exercise and a set time afterward, usually one minute. If your heart rate is 150 beats per minute when you stop and 125 a minute later, your one-minute recovery is 25.

Part of the rise in heart rate during exercise comes from a drop in the nerve signals that slow the heart (vagal tone). When you stop, those signals come back and your heart rate falls. Researchers read a slow fall in the first minute as a possible sign of weaker vagal activity [1].

Line chart: heart rate rises during exercise, peaks when you stop, then falls. The fall in the first minute is labeled heart rate recovery.

How is heart rate recovery measured in a clinic?

In an exercise test, your heart rate is recorded by ECG at peak effort and again one or two minutes later [4]. The exact routine after you stop changes the number, so each cut-off belongs to its own protocol:

  • Moving lightly in a cool-down after peak, measured at 1 minute: 12 beats per minute or less counted as abnormal [1–3].

  • Lying on the left side right after peak, for a heart ultrasound, with no cool-down, measured at 1 minute: 18 beats per minute or less counted as abnormal [3].

  • Measured at 2 minutes after a treadmill test: a fall of less than 22 beats per minute was the cut-off in a validation study of men referred for chest pain [4].

  • Measured at 2 minutes after a submaximal (not peak) test: 42 beats per minute or less counted as abnormal in a study of adults without known heart disease [18].

Cardiac rehabilitation studies have also measured recovery after moderate effort during supervised sessions, over 12 weeks [6, 16].

What did the research find?

In large studies of adults having exercise tests, and in a pooled analysis of general-population studies, a smaller fall in heart rate after exercise was associated with a higher rate of death from any cause in the following years. These are observational studies: they show a link, not that slow recovery causes harm.

  • The first large study. In 2,428 adults having an exercise test for diagnostic reasons at the Cleveland Clinic, followed for six years, 639 (26%) had a fall of 12 beats per minute or less, and 213 people in the whole group died. A low recovery stayed linked to a higher risk of death after adjusting for age, sex, medicines, exercise capacity and other risk factors [1].

  • A larger replication. In 9,454 adults referred for exercise ECG, followed for a median of 5.2 years, 8% of people with abnormal recovery died, compared with 2% of those with normal recovery. Among the 8,549 not taking beta-blockers, the adjusted hazard ratio was 2.13 (95% CI, 1.63–2.78) [2].

  • Pooled evidence. A 2017 meta-analysis pooled 9 prospective studies of adults from the general population, leaving out studies of people referred for symptoms (41,600 people, 2,082 deaths, mean follow-up 15 years). Slow recovery, compared with fast, was associated with a higher risk of death (pooled hazard ratio 1.68; 95% CI, 1.51–1.88). Each 10-beat smaller fall was associated with a hazard ratio for death of 1.09 (95% CI, 1.01–1.19). For cardiovascular events (5 studies, 34,267 people, 1,061 events), the pooled hazard ratio was 1.69 (95% CI, 1.05–2.71) [5].

Two limits matter. First, the single studies above were in people referred for exercise testing, many for suspected heart disease [1–4]. The pooled analysis [5] was not, and neither was a study that followed 5,234 adults without known heart disease for 12 years after a submaximal test at 10 primary care sites. There, a fall of 42 beats or less at 2 minutes was also associated with a higher risk of death (adjusted relative risk 1.55; 95% CI, 1.22–1.98; 312 deaths in the whole group) [18]. Second, heart rate recovery is a marker of outlook, not a test for blocked arteries. In 2,193 men referred for chest pain who had both a treadmill test and coronary angiography, recovery predicted survival but “failed to have diagnostic power” for finding coronary disease [4]. The same study called it “supplemental to, established scores,” not a replacement [4].

Is there a heart rate recovery chart by age?

We found no published age chart tied to health outcomes. The clinical cut-offs above are single values, used for adults of all ages in each study [1–4, 18].

Age does seem to matter, but the evidence is small and mixed. In 81 people in cardiac rehabilitation, recovery after submaximal effort was lower in older patients and in women [6]. A study of 21 trained adults aged 20 to 53 found recovery declined with age [7], while a study of 274 male elite athletes found adults had a larger one-minute fall than adolescents [8]. A chart that assigns “good” ranges by age goes beyond what these studies show.

What can your watch’s recovery number tell you?

Most watches measure heart rate with light through the skin of your wrist (photoplethysmography), not with ECG electrodes [10]. Studies find them reasonably accurate at rest and during sustained exercise, with more error when activity changes [10], and recovery is measured exactly when your heart rate is changing fast.

What the validation studies show:

  • The wrist reading lags. In 30 adults who did moderate exercise and then rested, one wrist device showed the fall in heart rate later than a 10-lead ECG in 97% of cases. The spread between its one-minute recovery values and the ECG’s was more than 20% on a treadmill and 11.7% on a bike [9].

  • Changing effort adds error. Across consumer and research-grade wearables, absolute heart rate error during activity was on average 30% higher than at rest [10].

  • Exercise type matters. In 50 adults, most wrist monitors agreed well with ECG on a treadmill, fewer did on a bike, and none of the devices tested was accurate on an elliptical with arm levers. A chest strap with electrodes agreed most closely across all conditions combined. This study measured heart rate during exercise, not recovery [11].

  • Skin tone: results conflict. One study found larger heart rate errors with darker skin [12]; another found no significant difference across skin tones [10]. A systematic review of 10 studies called the evidence inconclusive (4 found lower accuracy with darker skin, 4 found no effect, 2 were mixed) [13].

So, at most, compare a wrist number with your own earlier readings, taken the same way. It cannot be compared with the cut-offs above, which came from ECG readings under a fixed protocol. A wearable estimate is not a clinical measurement.

How does heart rate recovery compare with HRV and readiness scores?

Heart rate recovery and heart rate variability (HRV) both have outcome research behind them. That research used clinical exercise tests for heart rate recovery [5] and recordings of 10 seconds to 24 hours for HRV [21]. Wrist and ring estimates of HRV have not been shown to be interchangeable with ECG [22], and we found no published study that tested a readiness score against heart outcomes.

  • HRV in population studies. A meta-analysis of 8 studies, with 21,988 people without known heart disease, found that low HRV was associated with a higher risk of a first heart or blood vessel event [21]. Like heart rate recovery, this is an observational link.

  • HRV from a wrist or ring. These devices estimate pulse rate variability from light through the skin. A 2026 meta-analysis pooled 10 studies in healthy people, mostly at rest or under controlled conditions. It measured how far these estimates were from ECG, but there is no validated threshold for an acceptable difference, and the authors said the results should not be applied to sleep, exercise, stress or daily life, or “interpreted as evidence of interchangeability” [22]. In 13 healthy adults over 536 nights, five consumer devices’ overnight HRV differed from ECG by an average of about 6% to 16%, depending on the device [23].

  • Readiness scores. Many wearables show a daily “readiness” or “recovery” score built with the company’s own formula, and one validation study noted “little transparency” about which measurements go into these scores [23]. We found no published study that tested one of these scores against heart outcomes.

  • Where wrist sensors have been tested at scale. In a study of 419,297 smartwatch users who reported no atrial fibrillation, funded by the watch’s maker, 2,161 (0.52%) got an irregular-pulse alert. Of the 450 who returned a usable ECG patch, 34% (97.5% CI, 29–39) had atrial fibrillation on it. When the watch alerted again while the patch was worn, the patch showed atrial fibrillation 84% of the time (95% CI, 76–92) [24]. That is a rhythm alert, not a recovery or readiness number.

How do you measure your recovery more consistently?

If you want a number you can compare from one week to the next, keep the conditions the same:

  • Keep the workout running while your heart rate comes down. Leave it on for a couple of minutes after you stop, so the minute that matters is recorded.

  • Use the same activity and effort. Wrist accuracy changes with the type of exercise [9, 11], and studies used different cut-offs after peak and after submaximal tests [1, 18].

  • Do the same thing after you stop. Studies that had people keep moving lightly or lie down after the test used different cut-offs [1, 3].

  • Note what else changed. In a study of people with heart failure, those taking beta-blockers had lower one-minute recovery after a walking test [14]. In a small study of 30 security officers and nurses, recovery was lower after a night shift without sleep than after a normal night [15]. Never change a medicine because of a watch reading.

This page does not offer a training plan. Studies of whether exercise changes recovery are small and mixed. In two cardiac rehabilitation studies, recovery was higher after 12 weeks of supervised exercise than at the start, but they compared the same people before and after, so they can’t show the exercise caused the change [6, 16]. In another, 14 men with coronary artery disease had no change in recovery after 12 weeks of training [17]. If you want to know whether exercise could change your recovery, ask the team that knows your health.

When should you talk to your clinician?

Bring it up at your next appointment if your recovery trend has changed and stayed changed, or if you have questions about what your number means for you. Bring the trend, not one reading.

Some symptoms need attention whatever your watch says. Chest discomfort, such as pressure, squeezing or pain, and shortness of breath can be warning signs of a heart attack. The American Heart Association says to call 911 if you have them [20].

If you are in a cardiac rehabilitation program, ask your care team how they use your heart rate during and after sessions.

Frequently asked questions

What is a normal heart rate recovery?

In the best-known clinical studies, a fall of more than 12 beats per minute in the first minute after peak exercise, measured during a light cool-down, was counted as normal [1–3]. Other protocols use other cut-offs [3, 4, 18].

What does a low heart rate recovery mean?

In people having exercise tests, and in pooled studies of the general population, a low recovery was associated with a higher risk of death in later years [1, 2, 5]. It is one marker among many, not a diagnosis. In the one study that checked, it did not identify who had narrowed coronary arteries [4].

Is heart rate recovery the same as heart rate variability?

No. Heart rate recovery is the fall in heart rate after exercise. Heart rate variability is the change in time between one heartbeat and the next, measured over periods from about 2 minutes to 24 hours [19].

How accurate is Apple Watch or Garmin heart rate recovery?

We found no published study that validated the recovery feature of these watches specifically. In one study, a wrist optical sensor registered the fall in heart rate later than an ECG in 97% of cases, which affects a one-minute value [9], and wrist sensors make more errors when activity changes [10]. At most, compare the number with your own earlier readings, not with clinical cut-offs.

Can you improve your heart rate recovery?

Studies are small and mixed. In two cardiac rehabilitation studies, recovery was higher after 12 weeks of supervised exercise than before, but they compared the same people before and after, so they can’t show the exercise caused the change [6, 16]. Another small study found no change after 12 weeks of training [17]. Ask your clinician what fits you.

Follow Kento Health on LinkedIn for plain, sourced answers on heart health.

For program teams: see how Kento, a continuous cardiovascular care platform, uses exercise data in cardiac programs.

Kento Health

References

  1. Cole CR, Blackstone EH, Pashkow FJ, Snader CE, Lauer MS. Heart-rate recovery immediately after exercise as a predictor of mortality. N Engl J Med. 1999;341(18):1351-1357. doi:10.1056/NEJM199910283411804. PMID: 10536127

  2. Nishime EO, Cole CR, Blackstone EH, Pashkow FJ, Lauer MS. Heart rate recovery and treadmill exercise score as predictors of mortality in patients referred for exercise ECG. JAMA. 2000;284(11):1392-1398. doi:10.1001/jama.284.11.1392. PMID: 10989401

  3. Watanabe J, Thamilarasan M, Blackstone EH, Thomas JD, Lauer MS. Heart rate recovery immediately after treadmill exercise and left ventricular systolic dysfunction as predictors of mortality: the case of stress echocardiography. Circulation. 2001;104(16):1911-1916. PMID: 11602493

  4. Shetler K, Marcus R, Froelicher VF, et al. Heart rate recovery: validation and methodologic issues. J Am Coll Cardiol. 2001;38(7):1980-1987. doi:10.1016/s0735-1097(01)01652-7. PMID: 11738304

  5. Qiu S, Cai X, Sun Z, et al. Heart rate recovery and risk of cardiovascular events and all-cause mortality: a meta-analysis of prospective cohort studies. J Am Heart Assoc. 2017;6(5):e005505. doi:10.1161/JAHA.117.005505. PMID: 28487388

  6. Kligfield P, McCormick A, Chai A, Jacobson A, et al. Effect of age and gender on heart rate recovery after submaximal exercise during cardiac rehabilitation in patients with angina pectoris, recent acute myocardial infarction, or coronary bypass surgery. Am J Cardiol. 2003;92(5):600-603. doi:10.1016/s0002-9149(03)00733-1. PMID: 12943886

  7. Zubac D, Goswami N, Ivančev V, Valić Z, et al. Independent influence of age on heart rate recovery after flywheel exercise in trained men and women. Sci Rep. 2021;11(1):12011. doi:10.1038/s41598-021-91565-w. PMID: 34103623

  8. Suzic Lazic J, Dekleva M, Soldatovic I, et al. Heart rate recovery in elite athletes: the impact of age and exercise capacity. Clin Physiol Funct Imaging. 2017;37(2):117-123. doi:10.1111/cpf.12271. PMID: 26147945

  9. Bretonneau Q, Peruque-Gayou E, Wolfs E, Bosquet L. Accuracy of heart-rate-recovery parameters assessed from a wrist-worn photoplethysmography monitor (Polar Unite). Int J Sports Physiol Perform. 2023;19(1):13-18. doi:10.1123/ijspp.2023-0120. PMID: 37917971

  10. Bent B, Goldstein BA, Kibbe WA, Dunn JP. Investigating sources of inaccuracy in wearable optical heart rate sensors. NPJ Digit Med. 2020;3:18. doi:10.1038/s41746-020-0226-6. PMID: 32047863

  11. Gillinov S, Etiwy M, Wang R, Blackburn G, et al. Variable accuracy of wearable heart rate monitors during aerobic exercise. Med Sci Sports Exerc. 2017;49(8):1697-1703. PMID: 28709155

  12. Shcherbina A, Mattsson CM, Waggott D, et al. Accuracy in wrist-worn, sensor-based measurements of heart rate and energy expenditure in a diverse cohort. J Pers Med. 2017;7(2):3. doi:10.3390/jpm7020003. PMID: 28538708

  13. Koerber D, Khan S, Shamsheri T, Kirubarajan A, et al. Accuracy of heart rate measurement with wrist-worn wearable devices in various skin tones: a systematic review. J Racial Ethn Health Disparities. 2023;10(6):2676-2684. PMID: 36376641

  14. Lindemberg S, Chermont S, Quintão M, Derossi M, et al. Heart rate recovery in the first minute at the six-minute walk test in patients with heart failure. Arq Bras Cardiol. 2014;102(3):279-287. doi:10.5935/abc.20140036. PMID: 24714794

  15. Cincin A, Sari I, Oğuz M, Sert S, et al. Effect of acute sleep deprivation on heart rate recovery in healthy young adults. Sleep Breath. 2015;19(2):631-636. doi:10.1007/s11325-014-1066-x. PMID: 25319876

  16. Mahdavi Anari L, Ghanbari-Firoozabadi M, Ansari Z, et al. Effect of cardiac rehabilitation program on heart rate recovery in coronary heart disease. J Tehran Heart Cent. 2015;10(4):176-181. PMID: 26985205

  17. Currie KD, Rosen LM, Millar PJ, McKelvie RS, MacDonald MJ. Heart rate recovery and heart rate variability are unchanged in patients with coronary artery disease following 12 weeks of high-intensity interval and moderate-intensity endurance exercise training. Appl Physiol Nutr Metab. 2013;38(6):644-650. doi:10.1139/apnm-2012-0354. PMID: 23724882

  18. Cole CR, Foody JM, Blackstone EH, Lauer MS. Heart rate recovery after submaximal exercise testing as a predictor of mortality in a cardiovascularly healthy cohort. Ann Intern Med. 2000;132(7):552-555. doi:10.7326/0003-4819-132-7-200004040-00007. PMID: 10744592

  19. Shaffer F, Ginsberg JP. An overview of heart rate variability metrics and norms. Front Public Health. 2017;5:258. doi:10.3389/fpubh.2017.00258. PMID: 29034226

  20. American Heart Association. Warning signs of a heart attack. https://www.heart.org/en/health-topics/heart-attack/warning-signs-of-a-heart-attack (accessed Nov 23, 2026)

  21. Hillebrand S, Gast KB, de Mutsert R, et al. Heart rate variability and first cardiovascular event in populations without known cardiovascular disease: meta-analysis and dose-response meta-regression. Europace. 2013;15(5):742-749. doi:10.1093/europace/eus341. PMID: 23370966

  22. Xu S, Liu H, Liu Z, Su P, Gu Z. Accuracy of photoplethysmography-derived pulse rate variability compared with electrocardiography-derived heart rate variability: a systematic review and meta-analysis. Sensors (Basel). 2026;26(16):5192. doi:10.3390/s26165192. PMID: 42655500

  23. Dial MB, Hollander ME, Vatne EA, Emerson AM, Edwards NA, Hagen JA. Validation of nocturnal resting heart rate and heart rate variability in consumer wearables. Physiol Rep. 2025;13(16):e70527. doi:10.14814/phy2.70527. PMID: 40834291

  24. Perez MV, Mahaffey KW, Hedlin H, et al. Large-scale assessment of a smartwatch to identify atrial fibrillation. N Engl J Med. 2019;381(20):1909-1917. doi:10.1056/NEJMoa1901183. PMID: 31722151