AI in cardiology: where it helps, and who decides
A sourced guide to artificial intelligence in cardiology for cardiology and informatics leaders: what the evidence shows, where its limits are, and what to ask a vendor.
AI in cardiology has published evidence today in a few specific places: reading the electrocardiogram (ECG) for signs of a weak heart, measuring heart function on echocardiograms, flagging irregular rhythms from wearables, and drafting clinical notes. In 2024, the American Heart Association said few AI tools had yet been shown to improve cardiovascular care enough to be widely adopted [1]. AI is useful where it has been tested, and it is safest when a clinician reviews and decides.
Where is AI used in cardiology today?
Four uses have peer-reviewed evidence behind them, each at a different stage. Some have randomized trials; others have accuracy studies only. The difference matters when you size up a tool.
Reading the ECG for a weak heart (AI-ECG). Researchers trained a neural network on paired 12-lead ECGs and echocardiograms from 44,959 patients at one academic medical center to spot an ejection fraction of 35% or less from the ECG alone. In a separate set of 52,870 patients, it reached an area under the curve of 0.93, with a sensitivity of 86.3% and a specificity of 85.7% [2]. That is an accuracy study, not a test of patient outcomes. The step that followed was a randomized test in practice: in the EAGLE trial, 120 primary care teams were cluster-randomized, and 22,641 adults without prior heart failure had an ECG in routine care. Giving clinicians the AI result increased new diagnoses of low ejection fraction (50% or less) within 90 days, from 1.6% in the usual-care arm to 2.1% in the AI arm (odds ratio 1.32, 95% CI 1.01 to 1.61) [3].
Measuring heart function on echocardiograms. In a blinded, randomized trial of 3,495 echocardiograms at one US medical center, an AI tool or a sonographer made the first estimate of left ventricular ejection fraction, and a cardiologist made the final call without knowing which one went first. The cardiologist changed the estimate substantially (by more than 5%, the trial’s threshold) in 16.8% of AI-first studies and 27.2% of sonographer-first studies (difference −10.4 percentage points, 95% CI −13.2 to −7.7) [4]. Note the design: the AI proposed and a cardiologist decided in every case. Authorized imaging software exists too: the FDA list places some cardiac CT and ultrasound tools under its radiology panel [5].
Flagging rhythm problems between visits. In the Apple Heart Study, 419,297 people who reported no atrial fibrillation (AFib) let a smartwatch algorithm check their pulse. Over a median of 117 days, 2,161 (0.52%) received an irregular-pulse notification. Among the 450 who returned a usable ECG patch, 34% had AFib on the patch (97.5% CI 29% to 39%). Of the 86 who got another notification while wearing the patch, 72 had AFib on the patch at the same time (positive predictive value 0.84, 95% CI 0.76 to 0.92) [6]. A notification is a reason for a clinical test, not a diagnosis. The AHA statement adds that consumer wearables “may or may not contain FDA-cleared components” and differ in signal processing, data security, “level of clinical validation, and data integration into medical records” [1]. Before a health system acts on home data, it needs to know which of those it is getting. For what wrist sensors can and cannot measure after exercise, see our guide to heart rate recovery.
Drafting clinical notes. Ambient AI scribes record a visit and draft the note. In a randomized trial of 238 outpatient physicians across 14 specialties at one academic health system, one of two scribe applications reduced time spent writing notes by 9.5% compared with usual care (95% CI −17.2% to −1.8%); the other showed no significant change (−1.7%, 95% CI −9.4% to +5.9%) [7]. Physicians reported clinically significant inaccuracies “occasionally,” and the authors call for “ongoing vigilance” [7]. Drafts still need a clinician’s review.
The U.S. Food and Drug Administration (FDA) keeps a public list of AI-enabled medical devices it has authorized; the FDA notes the list is not comprehensive. As downloaded on November 23, 2026, it held 1,614 devices, 154 of them with cardiovascular as the lead review panel [5].
Why should clinicians be able to see where an AI answer came from?
Because a clinician can only take responsibility for an answer they can check. Few AI tools in cardiology have yet been shown to improve care enough to be widely adopted [1], so transparency matters: what the tool looked at, how it reached its output, and where it is known to fail.
Regulators say the same. The FDA, with Health Canada and the UK’s MHRA, describes transparency as clearly sharing a device’s intended use, development, performance and, when available, its “logic”: “how an output or result was reached” [8]. The same principles describe it as good practice to identify any patient populations “not well represented in training or clinical datasets” [8].
Seeing the source also matters for fairness. The AHA statement warns that a model can perform well overall “while still performing poorly for people of underrepresented races and ethnicities” [1]. And AI can only reason over the data it receives. If home readings, rehab sessions and outside results never reach the record, the model works on part of the patient’s story. A clinician who sees what the answer was built from can spot what was missing.
Privacy and security weigh on buyers too. In a Sage Growth Partners survey of 101 health care C-suite executives, reported by the American Hospital Association in September 2025, nearly 70% completely or somewhat agreed that data privacy and security concerns are a major barrier to AI adoption [9].
Who decides when AI is involved in cardiac care?
The clinician decides. AI can propose: a flag, a measurement, a draft. A clinician reviews it, edits or rejects it, and signs, and only then does it reach the record or the patient. That order keeps the clinical decision with the licensed clinician and the care team.
The research above follows that order. In the EAGLE trial, the AI result went to the primary care team, which chose whether to order an echocardiogram [3]. In the echocardiography trial, a cardiologist made the final assessment every time [4]. The AHA statement notes that when an output comes from a “black box,” it can be hard to establish how the standard of care was defined [1]: one more reason to keep a person in the loop.
A review step only works if the reviewer can disagree. The same statement, discussing AI applied to the ECG, lists automation bias, the pull to accept what a machine suggests, among the uncertainties that robust clinical validation must address [1]. In practice, that means the clinician sees the inputs behind each proposal, can edit or reject it in one step, and is never asked to sign something they cannot check. It also means the work can be done without the AI when the clinician prefers, or when the tool is down.
How Kento applies it. Kento is a continuous cardiovascular care platform, and we build its AI, Kai, on one rule: Kai flags, a clinician decides. Kai does not diagnose, and your clinicians hold medical responsibility. How we build Kai · Kento for health systems

What should you ask an AI vendor in cardiology?
Use these questions in a vendor review. Each one has a reason behind it, and a good vendor will answer all of them in writing. Bring the cardiology lead, the chief medical information officer (CMIO), IT security and the privacy officer to the same review, so each answer is checked by the person who will live with it. Kento’s approach to AI is on How we build Kai.
Evidence. What published studies support this tool, and what design were they: retrospective, prospective or randomized? Ask for the studies themselves, not a summary.
Validation population. Who was it trained and tested on, and do they look like our patients by age, sex, race, ethnicity and care setting? The AHA calls for validation “in large diverse populations that minimizes bias” [1].
Regulatory status. Is it FDA-authorized? If so, for what intended use, and can you give us the submission number? If not, why do you believe it does not need to be? (The FDA’s list links each entry to its FDA database record [5].)
Where the data goes. Where is our patient data stored and processed, who can access it, is it used to train models, and will you sign a business associate agreement?
How outputs show their sources. Can a clinician see what each output was built from? Transparency principles include sharing a tool’s “logic” when available [8].
Who signs. Can anything the tool produces reach the record or the patient without a clinician’s review and signature? If so, which outputs, and who is accountable?
How errors are caught. How do clinicians report an error, how do you monitor performance after go-live, and what are the known failure modes? The FDA, Health Canada and MHRA transparency principles list “known biases or failure modes” and ongoing performance monitoring among the information worth sharing [8].
EMR integration. Does it work inside our electronic medical record (EMR), what does it read and write, and what does our IT team have to build?
Frequently asked questions
Is AI used in cardiology today?
Yes, in specific, tested places: ECG interpretation, echocardiogram measurement, rhythm notifications from wearables and note drafting [2–7]. The FDA’s list of AI-enabled devices includes 154 with cardiovascular as the lead review panel, as downloaded on November 23, 2026 [5].
Can AI read an ECG?
AI can estimate from a 12-lead ECG whether a patient is likely to have a weak heart pump. In a randomized trial in primary care, giving clinicians that result increased new diagnoses of low ejection fraction from 1.6% to 2.1% [3]. The clinician still orders the echocardiogram that confirms it.
Will AI replace cardiologists?
The trials described here did not test that. In them, AI proposed and clinicians decided [3, 4], and in 2024 the American Heart Association said few AI tools had yet been shown to improve care enough for wide adoption [1].
Is FDA clearance proof that an AI tool works?
Not on its own. Devices on the FDA’s AI list have met the FDA’s applicable premarket requirements for their intended use [5]; that does not show how a tool performs in your patients or setting. Ask the vendor for its published studies.
How does Kento use AI?
Kai, Kento’s AI, follows one rule: Kai flags, a clinician decides. Kai does not diagnose, and your clinicians hold medical responsibility. More at How we build Kai.
Talk to our team
Evaluating AI for your cardiology program? Talk to our team.
References
Armoundas AA, Narayan SM, Arnett DK, et al. Use of artificial intelligence in improving outcomes in heart disease: a scientific statement from the American Heart Association. Circulation. 2024;149(14):e1028-e1050. doi:10.1161/CIR.0000000000001201. PMID: 38415358.
Attia ZI, Kapa S, Lopez-Jimenez F, et al. Screening for cardiac contractile dysfunction using an artificial intelligence-enabled electrocardiogram. Nat Med. 2019;25(1):70-74. doi:10.1038/s41591-018-0240-2. PMID: 30617318.
Yao X, Rushlow DR, Inselman JW, et al. Artificial intelligence-enabled electrocardiograms for identification of patients with low ejection fraction: a pragmatic, randomized clinical trial. Nat Med. 2021;27(5):815-819. doi:10.1038/s41591-021-01335-4. PMID: 33958795.
He B, Kwan AC, Cho JH, et al. Blinded, randomized trial of sonographer versus AI cardiac function assessment. Nature. 2023;616(7957):520-524. doi:10.1038/s41586-023-05947-3. PMID: 37020027.
U.S. Food and Drug Administration. Artificial Intelligence-Enabled Medical Devices (list and CSV download). https://www.fda.gov/medical-devices/software-medical-device-samd/artificial-intelligence-enabled-medical-devices. Page content current as of September 4, 2026; accessed November 23, 2026.
Perez MV, Mahaffey KW, Hedlin H, et al. Large-scale assessment of a smartwatch to identify atrial fibrillation. N Engl J Med. 2019;381(20):1909-1917. doi:10.1056/NEJMoa1901183. PMID: 31722151.
Lukac PJ, Turner W, Vangala S, et al. Ambient AI scribes in clinical practice: a randomized trial. NEJM AI. 2025;2(12). doi:10.1056/AIoa2501000. PMID: 41497288.
U.S. Food and Drug Administration, Health Canada, Medicines and Healthcare products Regulatory Agency. Transparency for machine learning-enabled medical devices: guiding principles. June 2024. https://www.fda.gov/medical-devices/software-medical-device-samd/transparency-machine-learning-enabled-medical-devices-guiding-principles. Accessed November 23, 2026.
American Hospital Association. How do health executives view AI? 3 takeaways from new survey. September 9, 2025. https://www.aha.org/2025-09-09-how-do-health-executives-view-ai-3-takeaways-new-survey. Accessed November 23, 2026.